Implantation of cardiac electronic devices in active COVID-19 patients

Tijdschriftbijdrage - Tijdschriftartikel

Ondertitel:Results from an international survey

BACKGROUND: Cardiac implantable electronic device (CIED) implantation rates as well as the clinical and procedural characteristics and outcomes in patients with known active coronavirus disease 2019 (COVID-19) are unknown.

OBJECTIVE: The purpose of this study was to gather information regarding CIED procedures during active COVID-19, performed with personal protective equipment, based on an international survey.

METHODS: Fifty-three centers from 13 countries across 4 continents provided information on 166 patients with known active COVID-19 who underwent a CIED procedure.

RESULTS: The CIED procedure rate in 133,655 hospitalized COVID-19 patients ranged from 0 to 16.2 per 1000 patients (P <.001). Most devices were implanted due to high-degree/complete atrioventricular block (112 [67.5%]) or sick sinus syndrome (31 [18.7%]). Of the 166 patients in the study survey, the 30-day complication rate was 13.9% and the 180-day mortality rate was 9.6%. One patient had a fatal outcome as a direct result of the procedure. Differences in patient and procedural characteristics and outcomes were found between Europe and North America. An older population (76.6 vs 66 years; P <.001) with a nonsignificant higher complication rate (16.5% vs 7.7%; P = .2) was observed in Europe vs North America, whereas higher rates of critically ill patients (33.3% vs 3.3%; P <.001) and mortality (26.9% vs 5%; P = .002) were observed in North America vs Europe.

CONCLUSION: CIED procedure rates during known active COVID-19 disease varied greatly, from 0 to 16.2 per 1000 hospitalized COVID-19 patients worldwide. Patients with active COVID-19 infection who underwent CIED implantation had high complication and mortality rates. Operators should take these risks into consideration before proceeding with CIED implantation in active COVID-19 patients.

Tijdschrift: Heart Rhythm : The Official Journal of the Heart Rhythm Society
ISSN: 1547-5271
Issue: 2
Volume: 19
Pagina's: 206-216
Jaar van publicatie:2022
Trefwoorden:Aged, Atrioventricular Block/epidemiology, COVID-19/diagnosis, Comorbidity, Defibrillators, Implantable/statistics & numerical data, Female, Global Health/statistics & numerical data, Humans, Infection Control/instrumentation, Male, Middle Aged, Mortality, Outcome Assessment, Health Care, Pacemaker, Artificial/statistics & numerical data, Postoperative Complications/diagnosis, Prosthesis Implantation/adverse effects, Risk Factors, SARS-CoV-2/isolation & purification, Sick Sinus Syndrome/epidemiology, Surveys and Questionnaires, Cardiovasculaire en respiratoire geneeskunde
Toegankelijkheid:Open