< Terug naar vorige pagina

Publicatie

Can we attenuate ischaemia-reperfusion injury of allografts in a porcine left lung transplant models by adsorption of cytokines?

Tijdschriftbijdrage - Tijdschriftartikel

OBJECTIVES: Primary graft dysfunction resulting from ischaemia-reperfusion injury remains a major obstacle after lung transplantation (LTx) and is associated with morbidity and mortality. Continuous release of inflammatory cytokines, due to the process of ischaemia and reperfusion, triggers a complex cascade of apoptosis and necrosis resulting in graft dysfunction. Previous studies demonstrated successful graft improvement by cytokine filtration during ex vivo lung perfusion. We hypothesize that plasma cytokine filtration with CytoSorb® during in vivo graft perfusion immediately after implantation may attenuate ischaemia-reperfusion injury after left LTx in a porcine model. METHODS: Left porcine LTx was performed with allografts preserved for 24 h at 4°C. In the treatment group [T] (n = 7), a veno-venous shunt was created to insert the cytokine filter (CytoSorbents, Berlin, Germany). In the sham group [S] (n = 4), the shunt was created without the filter. Haemodynamic parameters, lung mechanics, blood gases and plasma cytokines were assessed during 6 h in vivo reperfusion. RESULTS: During 6 h of reperfusion, significant differences in plasma pro-inflammatory cytokine [interferon (IFN)-α, IFN-γ and interleukin (IL)-6] concentrations were observed between [T] and [S], but surprisingly with higher plasma levels in the [T] group. Plasma concentrations of other pro-inflammatory cytokines (IL-1β, IL-12p40, IL-4, IL-6, IL-8, IFN-α, IFN-γ and tumour necrosis factor-α) and anti-inflammatory cytokines (IL-10) did not find any evidence for a difference. Furthermore, our study failed to show meaningful difference in haemodynamics and blood gases. Also, no statistically significant differences were found between [T] and [S] in biopsies and wet-to-dry ratio at the end of the experiment. CONCLUSIONS: In our porcine left LTx model cytokine filtration did not achieve the intended effect. This is in contrast to previous studies with CytoSorb use during ex vivo lung perfusion as a surrogate LTx model. Our findings might highlight the fact that the theoretical benefit of inserting an additional cytokine adsorber to improve graft function in clinical practice should be critically evaluated with further studies.
Tijdschrift: EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY
ISSN: 1010-7940
Issue: 1
Volume: 63
Jaar van publicatie:2022
Toegankelijkheid:Open