< Terug naar vorige pagina

Publicatie

Overall performance of a drug-drug interaction clinical decision support system: quantitative evaluation and end-user survey

Tijdschriftbijdrage - Tijdschriftartikel

BACKGROUND: Clinical decision support systems are implemented in many hospitals to prevent medication errors and associated harm. They are however associated with a high burden of false positive alerts and alert fatigue. The aim of this study was to evaluate a drug-drug interaction (DDI) clinical decision support system in terms of its performance, uptake and user satisfaction and to identify barriers and opportunities for improvement. METHODS: A quantitative evaluation and end-user survey were performed in a large teaching hospital. First, very severe DDI alerts generated between 2019 and 2021 were evaluated retrospectively. Data collection comprised alert burden, override rates, the number of alert overrides reviewed by pharmacists and the resulting pharmacist recommendations as well as their acceptance rate. Second, an e-survey was carried out among prescribers to assess satisfaction, usefulness and relevance of DDI alerts as well as reasons for overriding. RESULTS: A total of 38,409 very severe DDI alerts were generated, of which 88.2% were overridden by the prescriber. In 3.2% of reviewed overrides, a recommendation by the pharmacist was provided, of which 79.2% was accepted. False positive alerts were caused by a too broad screening interval and lack of incorporation of patient-specific characteristics, such as QTc values. Co-prescribing of a non-vitamin K oral anticoagulant and a low molecular weight heparin accounted for 49.8% of alerts, of which 92.2% were overridden. In 88 (1.1%) of these overridden alerts, concurrent therapy was still present. Despite the high override rate, the e-survey revealed that the DDI clinical decision support system was found useful by prescribers. CONCLUSIONS: Identified barriers were the lack of DDI-specific screening intervals and inclusion of patient-specific characteristics, both leading to a high number of false positive alerts and risk for alert fatigue. Despite these barriers, the added value of the DDI clinical decision support system was recognized by prescribers. Hence, integration of DDI-specific screening intervals and patient-specific characteristics is warranted to improve the performance of the DDI software.
Tijdschrift: BMC MEDICAL INFORMATICS AND DECISION MAKING
ISSN: 1472-6947
Issue: 1
Volume: 22
Jaar van publicatie:2022
Toegankelijkheid:Open