An Application Example of Regularization: Time-varying Operational Modal Analysis
Boekbijdrage - Boekhoofdstuk Conferentiebijdrage
This paper presents an efficient nonparametric
time-varying time domain system identification method for the
Operational Modal Analysis (OMA) framework. OMA tackles industrial measurements of vibrating structures in real-life operating conditions without the exact knowledge of the excitation signal. In this work a method is provided to estimate the time-varying output autocorrelation function of vibrating structures and applied to a measurement of wind tunnel testing of an airplane. Using the proposed methodology, the estimated time-varying two-dimensional output autocorrelation model provides a good data-fit with respect to tracking of varying resonances.
time-varying time domain system identification method for the
Operational Modal Analysis (OMA) framework. OMA tackles industrial measurements of vibrating structures in real-life operating conditions without the exact knowledge of the excitation signal. In this work a method is provided to estimate the time-varying output autocorrelation function of vibrating structures and applied to a measurement of wind tunnel testing of an airplane. Using the proposed methodology, the estimated time-varying two-dimensional output autocorrelation model provides a good data-fit with respect to tracking of varying resonances.
Boek: PROCEEDINGS OF THE 25TH MINISYMPOSIUM OF THE DEPARTMENT OF MEASUREMENT AND INFORMATION SYSTEMS BUDAPEST UNIVERSITY OF TECHNOLOGY AND ECONOMICS
Pagina's: 16-19
Aantal pagina's: 4
Jaar van publicatie:2018