< Terug naar vorige pagina

Publicatie

Ictal autonomic changes as a tool for seizure detection: a systematic review

Tijdschriftbijdrage - Tijdschriftartikel

PURPOSE: Adequate epileptic seizure detection may have the potential to minimize seizure-related complications and improve treatment evaluation. Autonomic changes often precede ictal electroencephalographic discharges and therefore provide a promising tool for timely seizure detection. We reviewed the literature for seizure detection algorithms using autonomic nervous system parameters. METHODS: The PubMed and Embase databases were systematically searched for original human studies that validate an algorithm for automatic seizure detection based on autonomic function alterations. Studies on neonates only and pilot studies without performance data were excluded. Algorithm performance was compared for studies with a similar design (retrospective vs. prospective) reporting both sensitivity and false alarm rate (FAR). Quality assessment was performed using QUADAS-2 and recently reported quality standards on reporting seizure detection algorithms. RESULTS: Twenty-one out of 638 studies were included in the analysis. Fifteen studies presented a single-modality algorithm based on heart rate variability (n = 10), heart rate (n = 4), or QRS morphology (n = 1), while six studies assessed multimodal algorithms using various combinations of HR, corrected QT interval, oxygen saturation, electrodermal activity, and accelerometry. Most studies had small sample sizes and a short follow-up period. Only two studies performed a prospective validation. A tendency for a lower FAR was found for retrospectively validated algorithms using multimodal autonomic parameters compared to those using single modalities (mean sensitivity per participant 71-100% vs. 64-96%, and mean FAR per participant 0.0-2.4/h vs. 0.7-5.4/h). CONCLUSIONS: The overall quality of studies on seizure detection using autonomic parameters is low. Unimodal autonomic algorithms cannot reach acceptable performance as false alarm rates are still too high. Larger prospective studies are needed to validate multimodal automatic seizure detection.
Tijdschrift: Clin Auton Res
ISSN: 0959-9851
Issue: 2
Volume: 29
Pagina's: 161 - 181
Jaar van publicatie:2019
BOF-keylabel:ja
IOF-keylabel:ja
BOF-publication weight:1
CSS-citation score:3
Auteurs:International
Authors from:Government, Higher Education
Toegankelijkheid:Open