< Back to previous page

Publication

Multi-Physical Time- and Frequency-Domain Fault Detection and Isolation Technique for Power-Electronic Converters in DFIG Wind Turbines

Journal Contribution - Journal Article

A multi-physical time- and frequency-domain fault detection and isolation (FDI) method for power-electronic converters (PECs) of wind turbines is presented in this paper, with focus on open-circuit faults and the doubly-fed induction generator (DFIG) drivetrain topology. In order to reduce the risk of false alarms, the proposed approach combines fault indicators based on time- and frequency-domain analysis of the electrical signals, as well as frequency-domain analysis of vibration signals. The effectiveness of the method is illustrated on test bench data recorded in different healthy and faulty operating modes.
Journal: IEEE Transactions on Power Electronics
ISSN: 0885-8993
Issue: 4
Volume: 36
Pages: 3793-3802
Publication year:2021
Keywords:Condition monitoring, semiconductor reliability, DFIG, wind turbines, open-circuit faults, fault diagnostic and isolation, power electronic converter
BOF-keylabel:yes
IOF-keylabel:yes
BOF-publication weight:6
Authors:International
Authors from:Higher Education