Aerothermal response of ceramic matrix composites to nitrogen plasma at temperatures above 2000K

Journal Contribution - Journal Article

Carbon/silicon carbide composites are tested at surface temperature above 2000 K in a high-enthalpy nitrogen flow at 2000 Pa, generated by an inductively coupled Plasmatron. Their altered surface is analyzed using scanning electron microscopy. Comparisons with experiments in air plasma at similar heat flux and pressure conditions suggest that the sole presence of nitrogen prevents the occurrence of temperature jump effect observed for this class of materials in flows containing oxygen reactants. Optical emission spectroscopy measurements near the surface confirm a lower volatility for the material tested in nitrogen compared to air.
Journal: Aerospace Science and Technology
ISSN: 1270-9638
Volume: 39
Pages: 1-5
Publication year:2014
Keywords:Ceramic-matrix composites (CMCs), Corrosion, Plasma testing