This study compares three different hyaluronate formulations and evaluates functionality, time of satisfactory pain relief and also the delay in performing a total hip arthroplasty. One hundred and twenty patients (126 hips) received viscosupplementation with one of the three hyaluronate formulations. All patients were candidate for surgical treatment with a total hip arthroplasty. Three different products were consecutively used: Adant (R), Synocrom (R) or Synvisc (R). Patients were assessed 6 weeks after each infiltration using Visual Analogue Scale and Harris Hip Score. The Harris Hip Score increased significantly in two of the three groups compared to baseline, but no statistical significant difference was noted between the groups. Viscosupplementation provides significant pain reduction in two of the three groups. There is no significant difference in duration of the effect of the first infiltration between the three groups. The positive effect was still ongoing at the end point of the study in 46 hips: 51% of the patients did not undergo total hip arthroplasty, 3 years after viscosupplementation.
Journal: Archives of Orthopaedic and Trauma Surgery
ISSN: 0936-8051
Issue: 3
Volume: 128
Pages: 275 - 280
Publication year:2008
BOF-keylabel:yes
IOF-keylabel:yes
BOF-publication weight:1
CSS-citation score:1
Authors:International
Authors from:Higher Education